SAFETY INSTRUCTIONS
• Always take care when moving the appliance as it is heavy. Always use safety gloves and
enclosed footwear.
• Do not pull the appliance by the handle.
• Install the appliance in a safe and suitable place that meets installation requirements.
• Keep the minimum distance from other appliances and units.
• Before mounting the appliance, check if the appliance door opens without restraint.
• The appliance is equipped with an electric cooling system. It must be operated with the
electric power supply.
• The built-in unit must meet the stability requirements of DIN 68930.
Cabinet minimum height (Cabinet under the work‐
top minimum height)
Cabinet width
Cabinet depth
Height of the front of the appliance
Height of the back of the appliance
Width of the front of the appliance
Width of the back of the appliance
Depth of the appliance
Built in depth of the appliance
Depth with open door
Ventilation opening minimum size. Opening placed
on the bottom rear side
Mains supply cable length. Cable is placed in the
right corner of the back side
Mounting screws
2.2 Electrical connection
WARNING!
Risk of fire and electric shock.
• All electrical connections should be made by a qualified electrician.
• The appliance must be earthed.
• Make sure that the parameters on the rating plate are compatible with the electrical ratings
of the mains power supply.
32/112
444 (460) mm
560 mm
550 (550) mm
455 mm
440 mm
595 mm
559 mm
567 mm
546 mm
882 mm
560x20 mm
1500 mm
3.5x25 mm