Commissioning
®
Available in ReadWin
2000, HART
Commuwin II with Matrix address
Sensor type
Sensor type
IEC 751
Pt100
Pt200
JIS
Pt100
IEC 751
Pt500
Pt1000
Ni100
Ni1000
Edison Copper
Cu10
Winding No.
15
Pt100
SAMA
Ni120
Edison Curve
No. 7
Pt50
Pt100
GOST
Cu50
Cu100
Polynomial RTD
Callendar - van
Dusen (Pt100)
TC Type B
TC Type C
TC Type D
TC Type E
TC Type J
TC Type K
TC Type L
TC Type N
TC Type R
TC Type S
TC Type T
TC Type U
10 to 400 
10 to 2000 
-20 to 100 mV
Specific linearization and sensor matching
Selecting the sensor types ' C allendar-van-Dusen' or ' P olynomial RTD' improves the accuracy of the system or defines user-specific linearization of
resistance thermometers. A detailed description of the ' C allendar-van-Dusen' method and ' P olynomial RTD' linearization is provided in the Appendix
to these Operating Instructions.
76
Function group SENSOR 1
®
handheld module DXR275/375,
Lower range
Upper range
value
value
-328°F (-200 °C)
1562 °F (850 °C)
-328°F (-200 °C)
1562 °F (850 °C)
-328°F (-200 °C)
1200 °F (649 °C)
-328°F (-200 °C)
482 °F (250 °C)
-328°F (-200 °C)
482 °F (250 °C)
-76 °F (-60 °C)
482 °F (250 °C)
-76 °F (-60 °C)
302 °F (150 °C)
-148 °F (-100 °C)
500 °F (260 °C)
-148 °F (-100 °C)
1292 °F (700 °C)
-94 °F (-70 °C)
518 °F (270 °C)
-328°F (-200 °C)
2012 °F (1100
-328°F (-200 °C)
-328°F (-200 °C)
1562 °F (850 °C)
-328°F (-200 °C)
392 °F (200 °C)
392 °F (200 °C)
-328°F (-200 °C)
-328°F (-200 °C)
1562 °F (850 °C)
1562 °F (850 °C)
32 °F (0 °C)
32 °F (0 °C)
3308 °F (1820
32 °F (0 °C)
-454 °F (-270 °C)
4208 °F (2320
-346 °F (-210 °C)
-454 °F (-270 °C)
4523 °F (2495
-328°F (-200 °C)
-454 °F (-270 °C)
1832 °F (1000
-58 °F (-50 °C)
-58 °F (-50 °C)
2192 °F (1200
-454 °F (-270 °C)
-328°F (-200 °C)
2501 °F (1372
10 
10 
1652 °F (900
-20 mV
2372 °F (1300
3214 °F (1768
3214 °F (1768
752 °F (400 °C)
1112 °F (600 °C)
400 
2000 
100 mV
min. range
18 °F (10 °C)
18 °F (10 °C)
18 °F (10 °C)
18 °F (10 °C)
18 °F (10 °C)
18 °F (10 °C)
18 °F (10 °C)
18 °F (10 °C)
18 °F (10 °C)
18 °F (10 °C)
18 °F (10 °C)
°C)
18 °F (10 °C)
18 °F (10 °C)
18 °F (10 °C)
18 °F (10 °C)
18 °F (10 °C)
900 °F (500 °C)
900 °F (500 °C)
°C)
900 °F (500 °C)
90 °F (50 °C)
°C)
90 °F (50 °C)
90 °F (50 °C)
°C)
90 °F (50 °C)
90 °F (50 °C)
°C)
900 °F (500 °C)
900 °F (500 °C)
°C)
90 °F (50 °C)
90 °F (50 °C)
10 
°C)
100 
°C)
5 mV
°C)
°C)
°C)
®
ReadWin
2000
DXR275/375,
FieldCare
+
+
 SW 01.03.00
 SW 01.03.00
 SW 01.03.00
 SW 01.03.00
 SW 01.03.00
 SW 01.03.00
 SW 01.03.00
 SW 01.03.00
 SW 01.03.00
 SW 01.03.00
 SW 01.03.00
 SW 01.03.00
Endress+Hauser
TMT162
CW II-
Matrix
V3H0
-
-
-
-
-
-

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis