Herunterladen Inhalt Inhalt Diese Seite drucken

Operating The Unit - Royal Catering RCDA-800/23S Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
b) Using the time (8) / temperature (16) control knobs, set the desired values for
the operation of the unit.
c)
The "CLOSED" position of the control knobs closes the heating and countdown
circuits of the unit.
MODEL RCDA-400/6.8S
a) To start the unit, select and hold the power switch (6) for about 1 second.
There will be a characteristic sound and all the control panel icons (1) will be
highlighted. Selecting the button (6) again will turn off the unit.
b) Setting the operating temperature of the unit is carried out using the
temperature increase / decrease buttons (9, 10). The temperature value is
changed in 5°C increments.
c)
Setting the operating time of the unit is carried out by means of the buttons
for adjusting the operating time increasing / decreasing values (14, 15).
Adjustment of the operating time value takes place every 30 minutes with a
single selection of the button. Selecting and holding the value adjustment
button will change the value by 1 hour.
d) After defining the desired parameters (temperature and time), wait about 5
seconds until the system starts the process automatically.
MODEL RCDA-500/15S
a) To start the unit, select and hold the power switch (6) for about 1 second.
There will be a characteristic sound and all the control panel icons (1) will be
highlighted. Selecting the button (6) again will turn off the unit.
b) Set the operating temperature of the unit by selecting the temperature button
(7) from the control panel. The current value on the LCD screen (c) will flash.
Adjust the value using the increase/decrease value adjustment buttons (17,
18). The temperature value is changed in 5°C increments.
c)
Set the operating time of the unit by selecting the time function button (13)
from the control panel. The current value on the LCD screen (c) will flash.
Adjust the value using the increase/decrease value adjustment buttons (17,
18). Adjustment of the operating time value takes place every 30 minutes with
a single selection of the button. Selecting and holding the value adjustment
button will change the value by 1 hour.
d) After defining the desired parameters (temperature and time), wait about 5
seconds until the system starts the process automatically.

OPERATING THE UNIT

a) Familiarize yourself with the parameters/functions of the unit.
b) Plug the plug of the unit's power cord into an electrical outlet.
c)
Start the unit with the power switch.
d) Using the control panel, set the desired operating time and temperature.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Rcda-400/6.8sRcda-500/15s

Inhaltsverzeichnis