Fitting a unit door
1. Lift the fitting aids out to the
top, turn round and insert
into the adjacent openings.
2. Slide the fitting aids
4
up level with the unit door:
underside of stop edge of
fitting aid = upper edge of
unit door.
3. Unscrew the
counternuts
.
3
4. Suspend the attachment strut
on the unit door.
1
5. Fasten the attachment strut
6. Lift the fitting aids
out to the
4
top, turn round and insert into
the adjacent openings.
7. Screw the towing bracket
on the unit door (screws
bn
4 x 14).
• In the area of the unit door
handle a towing bracket
must be mounted.
• If required several brackets
can be mounted.
• To ensure the towing brack-
et is in a suitable position
with the attachment brack-
et, the adjacent measures
must be used.
.
1
8. Suspend the unit door on
the door of the appliance/
adjusting pins
. Screw
2
the counternuts
loosely
3
onto the adjusting pins.
9. Align the unit door flush with
the surrounding unit fronts.
Tighten counternuts
.
3
10. Adjust the depth of the unit
door Z: loosen the screws
.
7
11. Screw the attachment
bracket
into the
5
predrilled holes on the
appliance door using the
hexagonal screw
.
6
12.
Screw the appliance door
onto the unit door through
:
the attachment brackets
(screws 4x14).
13.
Adjust the depth of the
unit door Z.
14. Attach all the covers
,
8
9
.
bl
15. Screw on the attachment
bracket
in the area of
bm
the towing bracket.
16. The opening resilience of
the door can be adjusted.
Adjust using the Allen key
provided:
-
Turn clockwise for stronger
resilience.
-
Turn anticlockwise for
weaker resilience (factory
setting).
,
GB
25