PROBLEMS
Machine does not start
Water
Water pressure too low: the gauge shows pressure below 2 bar
(green lamp on?), the display shows the text H
Machine does not start
Material
- Product too dry in mixing chamber
(mortar pump seized? red lamp on?)
Machine does not start
Grid
-Grid not inserted completely, the display shows the text Bloc
Machine does not start
Air
- The air pressure, with jet valve completely open, does not fall
below the minimum pressure value on the machine pressure switch
(table 1)
Machine does not start
Electrical current
and compressor does
- No current delivered to connector of site panel
not start and the blue
(fuses?)
light is OFF
- No power delivered to machine
(defective connector connection? loose cable?)
- Main switch not ON
Machine does not start
Electrical current
but compressor starts
- Start selector switch not in correct position
- Mixing chamber open
(start/stop pushbutton lamp on?)
- Mortar pump motor connector not inserted
(start/stop pushbutton lamp on?)
- Low water pressure switch trips on start-up
(water pump switched on "VHH DOVR PDFKLQH GRHV QRW VWDUW GXH WR
ZDWHU
Machine does not stop
Air
DQGRU FRPSUHVVRU
- Air hose defective
does not stop
(hose cut? Air leaks from couplings?
- Compressor air supply low
- Jet air valve faulty (blocked in open position)
Machine stops after
Water
starting up
- ,QWDNH ¿OWHU FORJJHG
 3UHVVXUH UHGXFHU ¿OWHU FORJJHG
- Water hose too long and/or too narrow
 :DWHU VXSSO\ LQVX FLHQW
IMER INTERNATIONAL S.p.A.
KOINE 3.1
CAUSES
O
2
28
REMEDIES
- Check that water is delivered from the supply
hose
 &KHFN WKDW WKH ZDWHU ¿OWHU LV FOHDQ
- Check that the water pump is switched on
- If the pump collects from a tank, check that it has
been primed and there are
no leaks from couplings
- Initial start-up not performed correctly (see
para.11)
 :DWHU ÀRZ UDWH VHWWLQJ WRR ORZ VHH SDUD
- No water delivered to mixing chamber
(water inlet obstructed, water solenoid valve
malfunction)
-Check that the grid is positioned correctly
- Check that the air hose is not bent or obstructe-
do
- Check that the jet nozzle is perfectly clean
- Check points listed alongside
- Check points listed alongside
- Check the air hose and couplings in particular
and replace if necessary
 &KHFN DLU ¿OWHU VHH SDUD 
- Check compressor relief valve
 &KHFN SRLQWV OLVWHG DORQJVLGH FOHDQ ¿OWHUV
FKHFN IRU DGHTXDWH ÀRZ UDWH IURP WKH ZDWHU KRVH
(at least 10-12 l/min if working with lime-cement
based plaster, at least 15-20 l/min with gypsum
based plasters) and replace hose if necessary or
collect water from an auxiliary tank