No.
3 Ph
1
Typ description
2
Serial number
3
Impeller diameter
Temperature of medium
4
5
Immersion depth
6
Weight
7
Hmax (delivery head max)
8
Hmin (delivery head min)
9
Qmax (delivery volume max)
10
Standard
11
Construction product test lab
12a
Year type test
12b
Declaration of performance
13
Build year
14
Motor type
15
IE Marking
16
Frequency
17
Voltage - 3Phase
18
Nominal current - 3Phase
19
Motor RPM
20
Voltage - Star Connection
Nominal current Star
21
connection
22
Insulation class
23
Power P1
24
Cos phi
25
Protection class
26
Power P2
27
Operating class
Text field sales
28
29
30
31
32
The rated (nominal) values can be found on the type plate.
Nominal input data relate to:
an ambient temperature of -20 °C to 40 °C
maximum temperature of the medium 40 °C
continuous operation S1 and
rated supply voltage
The connecting cables are designed for rated operation
where they are:
separately routed,
permanently submerged and/or attached to surfaces
and/or passing through air, and
at a maximum ambient temperature of 40 °C
If the routing and/or ambient temperature of the connect-
ing cables differs from this, the standards and regulations
applicable at the installation site must be observed. If the
type of operation and/or rated power supply is different,
the tolerances specified in EN 60034 must be observed
and the installation adjusted in accordance with the stan-
dards and regulations applicable at the installation site.
Note:
Conditions at the installation site must conform to all de-
tails on the rating plate. In the case of uncertainty, the
manufacturer must be consulted before commissioning.
3 Ph Ex
Typ description
Serial number
Impeller diameter
Temperature of medium
Immersion depth
Weight
Hmax (delivery head max)
Hmin (delivery head min)
Qmax (delivery volume max)
Standard
Construction product test lab
Year type test
Declaration of performance
Build year
Motor type
IE Marking
Frequency
Voltage - 3Phase
Nominal current - 3Phase
Motor RPM
Voltage - Star Connection
Nominal current Star
connection
Insulation class
Power P1
Cos phi
Protection class
Power P2
Operating class
Ex-certification number
Ex-test lab
Ex-Designation
Ex-i- power circuit details
Text field sales
3.3.2. Motor
The three-phase asynchronous motor consists of a sta-
tor and the motor shaft with the rotor set. The lead for
supplying power is designed for the maximum mechan-
ical power in accordance with the characteristic curve or
data plate of the pump. The cable entries and the lead
are sealed watertight against the conveyed medium. The
shaft bearings are robust, maintenance-free and perma-
nently greased roller bearings. All motors are also avail-
able in explosion-proof design in accordance with ATEX
Ex II 2 G EExd.
General motor data
Mode of operation
S1
Insulation class
H (180°C)
IP Code
IP68
Standard cable length 10 m
Shaft sealing
Silicon carbide / silicon carbide (on the
motor side),
slide ring seal
silicon carbide / silicon carbide (on the
wetted side)
Bearings
one grooved ball bearing (above)
one double-row angular contact ball
bearing (below)
3.3.3. Monitoring systems
The unit is fitted with various safety monitoring devices.
The following Table gives an overview of the available op-
tions.
Motor type Motor version
ET...
Motor in midflow, thermal monitoring for winding,
monitoring of the oil chamber sealing
ET... EX
Motor in midflow, thermal monitoring for win-
ding, monitoring of the oil chamber sealing,
explosion-proof
Temperature sensors
All pumps are fitted with a set of temperature sensors in
the motor windings.
In pumps of standard design, the connections of the tem-
perature sensors are brought out via the connecting ca-
ble and are to be connected via the T1 and T3 conductor
ends of the connecting cable in the switch cabinet, so that
the motor is switched on again automatically after it has
cooled down.
Instead of the standard sensors, explosion-proof designs
have a set of temperature sensors with a higher triggering
temperature, that are to be connected via the conductor
ends T1 and T2 of the connecting cable so that, after they
have been triggered, a manual reset via a special protec-
tive combination in the switchgear is necessary.
The set of temperature sensors must be connected in the
switchgear so that it shuts off the switchgear in the event
of overheating.