Electrical connection

Warning! Risk of fire and electric shock.
All electrical connections should be made by a
qualified electrician.
The appliance must be earthed.
Make sure that the parameters on the rating plate
are compatible with the electrical ratings of the
mains power supply.
Always use a correctly installed shockproof socket.
Do not use multi-plug adapters and extension
cables.
Make sure not to cause damage to the mains plug
and to the mains cable. Should the mains cable
need to be replaced, this must be carried out by our
Authorised Service Centre.
Do not let mains cables touch or come near the
appliance door or the niche below the appliance,
especially when it operates or the door is hot.
4
590 (600) mm
560 mm
550 (550) mm
598 mm
579 mm
594 mm
558 mm
561 mm
540 mm
1007 mm
560x20 mm
1100 mm
4x25 mm
The shock protection of live and insulated parts
must be fastened in such a way that it cannot be
removed without tools.
Connect the mains plug to the mains socket only at
the end of the installation. Make sure that there is
access to the mains plug after the installation.
If the mains socket is loose, do not connect the
mains plug.
Do not pull the mains cable to disconnect the
appliance. Always pull the mains plug.
Use only correct isolation devices: line protecting
cut-outs, fuses (screw type fuses removed from the
holder), earth leakage trips and contactors.
The electrical installation must have an isolation
device which lets you disconnect the appliance from
the mains at all poles. The isolation device must
have a contact opening width of minimum 3 mm.
This appliance is supplied with a main plug and a
main cable.
Cable types applicable for installation or replace-
ment for Europe:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F, H05 V2V2-
F (T90), H05 BB-F
For the section of the cable refer to the total power on
the rating plate. You can also refer to the table:
Total power (W)
maximum 1380
maximum 2300
maximum 3680
The earth cord (green / yellow cable) must be 2 cm
longer than phase and neutral cables (blue and brown
cables).
Use
Warning! Risk of injury, burns and
electric shock or explosion.
Do not change the specification of this appliance.
Make sure that the ventilation openings are not
blocked.
Do not let the appliance stay unattended during
operation.
Section of the cable
(mm²)
3 x 0.75
3 x 1
3 x 1.5