(9)
IMPORTANT! Plug & Play - no further settings are required for this application
after successful connection to the inverter.
The Fronius Smart Meter records the current power at the feed-in point and
transfers the data to the inverter. By controlling the Ohmpilot, the inverter adjus-
ts any surplus energy that is available to zero. In detail, this takes place by conti-
nuously adjusting the heating element connected to the Ohmpilot. Surplus ener-
gy is consumed using the heating element in a continuously variable manner.
If no temperature sensor is fitted, an external source (e.g. gas-fired heating)
must be used to ensure the minimum temperature is met.
As an alternative, the Ohmpilot can ensure the minimum temperature. To do this,
a temperature sensor must be connected so that the Ohmpilot can measure the
temperature. This may result in electricity being sourced from the grid.
The maximum temperature must be set on the heating element thermostat. If
the heating element does not have a thermostat, the Ohmpilot can also carry out
this task as an alternative (see chapter
94
Automatic circuit breaker max. B16A
Ferrite (included in scope of supply)
Optional settings
on page 122).