Functional principle and features
Scope of delivery
•
ABUS smoke alarm device including built-in battery
•
User guide
•
Installation material
Technical data
•
Power supply
•
Smoke detection
•
Optical alarm display
•
Power consumption
•
Operating temperature
•
Humidity
•
Sound pressure
•
Alarm muting
•
Detection range
•
Installation location
DC 3 V lithium battery (built-in)
Photoelectric reflection
LED flashes once per second
<8 µA (standby) || <50 mA (alarm)
0 to 40 °C
10% to 93% (non-condensing)
> 85 dB (A)@3 m
10 minutes
Max. 40 m² within a room
Ceiling (only in interior spaces)
29