• If the batteries are defective, liquid may leak out.
Avoid contact! In case of accidental contact, rinse
with water. If the liquid gets into your eyes, seek ad-
ditional medical attention. Leaking battery fluid can
cause skin irritation, burns and chemical burns.
• Regularly visually inspect the connection cables on
the battery for damage. Have damaged cables re-
placed by a specialist.
• Never bypass the fuses. Never use a fuse with a rat-
ing other than the prescribed rating (amperes).

Residual risks

The device is state-of-the-art and has been built in ac-
cordance with the recognised technical safety rules.
However, individual residual risks can arise during op-
eration.
• Health hazard due to electrical power, with the use
of improper electrical connection cables.
• Furthermore, despite all precautions having been
met, some non-obvious residual risks may still re-
main.
• Residual risks can be minimised if the "Safety In-
structions" and the "Intended Use" together with the
operating manual as a whole are observed.
• Avoid accidental start-ups of the power generator.
• Use the device in the way that is recommended in
this operating manual. This is how to ensure that
your power generator provides optimum perfor-
mance.
7.

Technical data

Generator
Protection category
Continuous output P
(COP)
n
(230 V) (S1)
Continuous output P
(COP)
n
(400 V 3
) (S1)
~
Max. power P
(230 V) (S2
max
5min)
Max. power P
(400 V 3
max
5min)
Rated voltage U
n
Rated current I
(12 V DC)
n
Rated current I
(230 V)
n
Rated current I
(400 V 3
n
IP23M
1.5 kW
4.4 kW
1.67 kW
) (S2
~
5.0 kW
230 V
/ 400 V 3
~
8.3 A
7 A
)
7 A
~
www.scheppach.com
Frequency F
n
Performance class
Active power factor φ
Quality class
Drive motor type
Displacement
Max. power (engine)
Fuel
Tank contents
Engine oil type
Oil volume (approx.)
Weight
Temperature T
max
Max. installation altitude (above
sea level)
Battery type
Battery capacity
Subject to technical changes!
Operating mode S1 (continuous operation)
The machine can be operated continuously with the
specified power.
Operating mode S2 (short-term operation)
The machine may only be operated at the specified
power for a brief time (5 min.).
Information about the noise level measured in accord-
ance with applicable standards (EN ISO 3744:1995,
ISO 8528-10:1998):
Sound pressure L
Sound pressure L
Measurement uncertainty K
Wear hearing protection. Excessive noise can result in
a loss of hearing.
~
Single phase /
Three phase: 1
4-stroke, 1 cylin-
der, air-cooled
5.7 kW / 7.7 PS
pA
wA
50 Hz
G1
/ 0.8
B
418 cm
3
Diesel
16 l
10W30
1650 ml
136 kg
40
C
°
1000 m
Lead acid
36 Ah
76.56 dB
97 dB
3 dB
GB | 33