Electrical connection - connection diagrams
Safety instructions:
Caution! Any assembly work to the ventilation device may only be carried out after disconnecting the supply
voltage! The ventilation device is fitted with protective insulation according to Protection Class II, a protective
conductor connection is not required!
Make sure that the supply voltage of all connection lines is voltage-free (dead)! (Separation from the power
supply with a minimum contact opening of 3 mm, e.g. electric fuse).
Each electric circuit of this ventilation system must be fitted with a residual current protection (e.g. FI switch/
RCCB)!
Additional installations and electrical components in the ventilation unit are not allowed!
Connection diagrams for further fan functions upon request!