5. Edge mowing:
Define the mowing frequency.
Never – default setting
Once – the edges are mown once per
week.
Twice – the edges are mown twice per
week.
6. Secondary areas:
Enable secondary areas.
Inactive – default setting
Active – setting if secondary areas are to
be mowed. With the commands "Mowing
start" and "Start time-delayed mowing",
the mowing area (main area/secondary
area) must be selected. (
14.5)
10.15 Setting starting points
To set, either
● teach in starting points
or
● select the required starting point and
define it manually.
Teaching in starting points:
After pressing the OK button, the
robotic mower begins a new
learning run along the perimeter wire. If it
is not docked, it first travels to the docking
station. All the existing starting points are
deleted
If the starting points are taught in
manually, the STOP button must
not be pressed before opening the
flap.
During travel, up to 4 starting points can be
specified by opening the flap and pressing
the OK button.
Interrupting the learning procedure:
Manually – by pressing the STOP button.
Automatically – by obstacles at the edge of
the mowing area.
0478 131 9923 B - EN
● If the learning run has been interrupted
automatically, correct the position of the
perimeter wire and remove any
obstacles.
● Check the position of the robotic mower
before continuing the learning run. The
machine must either be located on the
perimeter wire or within the mowing
area with the front facing the perimeter
wire.
Ending the learning procedure:
Manually – following an interruption.
Automatically – after docking.
After docking or after the interruption, the
new starting points are saved by opening
the flap and confirming with OK.
Starting frequency:
The starting frequency defines how often a
mowing operation is to begin from a
starting point. The default setting is 2 of 10
mowing operations (2/10) at each starting
point.
● Change the starting frequency as
required after learning.
● If the learning procedure has been
aborted prematurely, send the robotic
mower back the to docking station via a
command. (
10.5)
Setting starting point 1 to 4
manually:
Determine the distance of the
starting points from the docking
station and define the starting
frequency.
The distance corresponds to that
covered from the docking station to
the starting point in metres, measured in a
clockwise direction.
The starting frequency can be between 0
of 10 mowing operations (0/10) and 10 of
10 mowing operations (10/10).
The docking station is
defined as starting point 0;
mowing operations are
started from here as standard.
The starting frequency corresponds
to the calculated residual value of
10 of 10 operations.
10.16 Safety
1. Disabling device
2. Level
3. Change PIN code
4. Start signal
5. Alarm signal
6. Menu signal
7. Child lock
8. Keylock
9. Link iMow and dock
1. Disabling device:
The disabling device is activated
with OK; the robotic mower can no
longer be operated.
The robotic mower must be disabled prior
to any maintenance or cleaning work, prior
to transportation and prior to inspection.
(
5.1)
● To deactivate the disabling device
function, press the illustrated button
combination.
2. Level:
Four safety levels can be set;
various locks and safety devices are
activated, depending on the level.
None:
The robotic mower is unprotected.
Low:
PIN code entry for linking the robotic
115