MOUNTING INSTRUCTIONS
6

Pin assignment

en
18
M O U N T I N G I N S T R U C T I O N S | deTem2 Core A/P, deTem4 Core A/P
2.
Attach the swivel mount port to the adapter. (
The mounting hole of the swivel mount port faces the back of the device.
3.
Loosely screw in the M5 screw to mount the two individual parts.
4.
Using an M5 screw, mount the swivel mount bracket to a machine or profile frame
through the mounting hole.
Torque: 4.5 Nm to 5 Nm
5.
Align the device in the bracket. (
The device can be rotated up to ± 270° in the bracket. Fine adjustment is
possible as an option via the slot on the front of the bracket. To do so, insert a
hexagon key into the slot and align the device by up to ± 9°.
6.
When the device is correctly aligned, tighten the M5 screw to mount the two
individual parts.
Torque: 3 Nm to 3.5 Nm
The device is firmly mounted in the bracket.
Removing the bracket
Removing the bracket:
L
Using a suitable tool (e.g., slotted screwdriver), press on the circlip of the bracket (1)
and pull the bracket off the device using a rotating movement (2).
System connection (M12, 5-pin)
2
1
5
3
4
System connection pin assignment (male connector, M12, 5-pin)
Pin
Wire color
1)
1
Brown
2
White
3
Blue
4
Black
5
Gray
1)
Applies to the connecting cables recommended as accessories.
J
)
K
)
Active unit
+24 V DC (voltage supply input)
OSSD1 (switching output 1)
0 V DC (voltage supply input)
OSSD2 (switching output 2)
Not assigned