7 Servicing/inspection
WARNING
Lubricant contaminating fluid handled
Hazard to persons and the environment!
▷ Using machine oil is only permitted if the oil is disposed of properly.
7.2.2.2.3 Lubricant quantity
Table 12: Lubricant quantity [l] depending on the impeller type
Impeller type
VX
7.2.2.2.4 Changing the lubricant
WARNING
Lubricants posing a health hazard and/or hot lubricants
Hazard to persons and the environment!
▷ When draining the lubricant take appropriate measures to protect persons and
the environment.
▷ Wear safety clothing and a protective mask if required.
▷ Collect and dispose of any lubricants.
▷ Observe all legal regulations on the disposal of fluids posing a health hazard.
WARNING
Excess pressure in the lubricant reservoir
Liquid spurting out when the lubricant reservoir is opened at operating
temperature!
▷ Allow the pump set to cool down to ambient temperature.
▷ Carefully pull off the mechanical seal.
Sanipump VX 50
Lubricant quantity
[l]
0,10