571
72.1
90-3.38
UG1274642
Fig. 9: Fitting the guide
hoop arrangement
Fig. 10: Fastening the claw
for single guide rail
Attaching the lifting
chain / lifting rope –
stationary wet installation
Attaching the lifting
chain/rope –
transportable wet-
installed model
5 Installation at Site
5.3.1.4 Fitting the guide hoop arrangement
1. Insert the ends of guide hoop 571 into the grooves of duckfoot bend 72.1.
2. Fasten the duckfoot bend to the tank/sump floor with 2 anchor bolts 90-3.38.
(ð Section 5.3.1.1, Page 67)
5.3.1.5 Preparing the pump set
Fastening the claw for single guide rail
1. Fasten claw 732 with screw 914.05 and disc 550.35 to the discharge flange (see
illustration opposite). Tighten the screw to a torque of 17 Nm.
Attaching the lifting chain / lifting rope
Stationary wet installation
1.
Attach the lifting chain or rope to the lug/eyebolt/bail at the pump set on the
opposite side of the discharge nozzle.
This attachment point achieves a forward inclination of the pump set towards the
discharge nozzle, which allows the pump claw to hook onto the duckfoot bend.
Transportable wet-installed model
1.
Attach the lifting chain or rope to the lug/eyebolt/bail at the pump set on the side
of the discharge nozzle.
Sanipump VX 50