Conditions on site
Aluminum transducer versions (nominal (rated) forces 2.5 kN, 5 kN and
10 kN)
C10 version
Threaded connector
Bayonet connector
Integrated cable
Despite the careful encapsulation, it makes sense to protect the transducers
against permanent exposure to moisture.
The force transducers must be protected against chemicals that could attack
their steel or aluminum.
With stainless steel force transducers, note that acids and all materials which
release ions will in general also attack stainless steels and their welded seams.
Should there be any corrosion, this could cause the force transducer to fail. In
this case, appropriate means of protection must be provided.
5.3

Deposits

Dust, dirt and other foreign matter must not be allowed to accumulate
sufficiently to conduct any of the measuring force around the transducer, thus
invalidating the measured value (force shunt). See marking in Fig. 5.1.
14
Protection
class
IP64
IP67
IP67
A04036_01_YI0_03 HBM: public
Test condition
All-round protection against splashing
water
0.5 hours under 1 m water column
0.5 hours under 1 m water column