Herunterladen Inhalt Inhalt Diese Seite drucken

Instructions For Installation; Technical Data; Installing The Power Unit; Electrical Connections - Harvia Xenio CX1104XW01 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 24
EN

INSTRUCTIONS FOR INSTALLATION

See WARNINGS AND NOTES!
See INSTALLATION IMAGES!

Technical data

Technical data
EN
Dimensions and safety
distances
Approved accessories
Installing the Power Unit › Image 1
Install the power unit in a dry area or sauna room (ambient temperature >0ºC). Note! Do not embed the power
unit into the wall, since this may cause excessive heating of the internal components of the unit and lead to
damage.
Electrical Connections › Image 2
Connect the wiring according to Figure 2. Tables show the wire and fuse sizes, depending on the heater output. For
more detailed installation instructions see the instructions for installation and use of the selected heater
model. Maximum load from control unit to heater is 9 kW.
Power Unit Fuse Faults
Replace a blown fuse by a new one with the same value. The location of the fuses in the power unit is shown in Figure
2.
If the fuse for the electronic card has blown, there is likely a fault in the power unit. Service is required.
If the lighting fuse (Figure 2) is broken, there is a fault in the lighting. Check the operation and wiring of the
lighting.
22
Model
Max. power kW
Operating voltages
Frequency Hz
Fuse
(400 V 3 N~) A
(230 V 3~) A
Supply cord
(400 V 3 N~) mm²
(230 V 3~) mm²
Connection cable type
Protection class
Weight kg
Storage temperature °C
Height mm
Width mm
Depth mm
Product min. space requirements mm
Harvia SFE Safety switch
CX110XW
9
400 V / 415 V 3N~
50 / 60
6.0 kW
3 x 10
9.0 kW
3 x 16
6.0 kW
3 x 20
9.0 kW
3 x 35
6.0 kW
min. 5 x 1,5
9.0 kW
min. 5 x 2,5
6.0 kW
min. 4 x 2,5
9.0 kW
min. 4 x 6
H07RN-F or equivalent
I / IPX5
1,7
0-50
225
284
80
300 x 300

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Xenio cx001wifi

Inhaltsverzeichnis