11
SPECIFICATIONS FOR THE Z6... LOAD CELLS
Type
Accuracy class according to OIML R 60
Max. numbers of load cell verification intervals (n
Max. capacity (E
Minimum load cell verification interval
(v
)
min
Nominal sensitivity (C
Tolerance on sensitivity for load applica
tion in specified direction
Temperature effect on sensitivity (TK
Temperature effect on zero balance (TK
Hysteresis error (d
Non‐linearity (d
lin
Creep (d
) in 30 min.
DR
Input resistance (R
Output resistance (R
Reference voltage (U
Nom. (rated) range of excitation voltage
(B
)
u
Isolation resistance (R
Nominal (rated) temperature range (B
Service temperature range (B
Storage temperature range (B
Safe load limit (E
Breaking load (E
Maximum capacity
Permissible dynamic load
(vibration bandwidth to DIN 50100)
Nominal (rated) displacement, approx.
Weight, approx.
16
)
max
)
n
3)
)
hy
3)
)
)
LC
)
0
)
ref
)
is
)
tu
)
tl
)
L
)
d
)
LC
kg
t
% of C
n
mV/V
%
3)
)
% of
C
C
/10 K
)
n
0
%
Ω
V
GΩ
)
T
°
°
C [
F]
% of
E
max
kg
% of
E
max
mm
kg
Z6FD1
D1
1000
50; 100; 200;
50; 100; 200;
500
1
0.0360
2
t+(1;-0.1)
t"0.0500
t"0.0080
t"0.0500
t"0.0125
t"0.0500
t"0.0170
t"0.0500
t"0.0180
t"0.0490
t"0.0166
350...480
356 "0.2
5
0.5...12
u5
-10...+40 [+14...+104]
-30...+70 [-22...+158]
-50...+85 [-58...+185]
150
300
50
100
200
100
100
100
0.27
0.31
0.39
0.5
0.5
0.5
Z6FC3
C3
3000
500
1
0.0090
2
"0.05
356 "0.12
500
100
0.6
0.5
Z6/M
SPECIFICATIONS