6
OPERATION
S
Dust, dirt and other foreign bodies must not be allowed to collect in such a way that
movement of the transducer (bellows) is restricted.
S
The gap for the overload stop and lateral stops must also be kept free of
contamination.
S
The play of the overload stop (for details see table "Specifications for the weighing
module") should be checked at regular intervals, for instance with a feeler gage, and
be readjusted if necessary.
S
The weighing modules should not be completely relieved of load. This prevents the
load application elements from lifting out.
S
Lateral displacements which exceed the maximum permissible value and do not act in
the direction of the stay rods should be avoided by aligning the other modules appro
priately, or should be absorbed by other stops or retention devices.
S
The play in the stay rods should be regularly checked and if necessary readjusted.
10
Z6/M
OPERATION