Menu item
Description
[EN]
[DE]
Activate hybrid mode
The flush is not actuated
during use (waterless
39
operation). A periodic flush is
[HybridMod]
actuated once the delay time
[HybridMod]
or interval has elapsed → See
the 'Select flush mode' chapter
for a detailed description.
Parameter
Flush time
50
[FlshTime]
Determines the duration of the
[Spülzeit]
flush after one use.
Detection time
51
Determines the minimum
[DetectT]
detection time within the
[VerweilZ]
detection range to be
recognised as a user.
Flush time for the interval
53
flush
[IntFlushT]
Is active when menu item 32
[IntervSpZ]
[Interval flush] is set to [1] or
[2].
Flush interval for interval
54
flush
[IntervalT]
Is active when menu item 32
[IntervalZ]
[Interval flush] is set to [1] or
[2].
Cleaning time
55
Defines the duration for which
[CleanTime]
the flush is suppressed when
[ReiniZeit]
menu item 25 [CleanMode]
[Reinigung] is started.
Flush time for hybrid mode
56
Is active when menu item 39
[HybFlshT]
[Activate hybrid mode] is set to
[HybFlshT]
[1] or [2].
Time out for hybrid mode
57
Is active when menu item 39
[HybTimOut]
[Activate hybrid mode] is set to
[HybTimOut]
[1].
Interval for hybrid mode
58
Is active when menu item 39
[HybIntT]
[Activate hybrid mode] is set to
[HybIntT]
[2].
18014405597129227 © 05-2022
971.384.00.0(00)
Application
• To reduce the water
consumption
• To optimise the flushing
out of the urinal
ceramic
• To prevent flushes due
to unintentional entry
into the detection range
Area
Factory setting
Off = [0]
Use = [1]
Off
Interval = [2]
1–15 s
7 s
3–15 s
7 s
1–200 s
5 s
1–168 h
24 h
1–20 min [...]
10 min [10]
1–15 s
7 s
5–720 min
60 min
10–1440 min
1440 min
EN
4 / 4