Specified measurement range: 5 - 100% of the measurement range
Frequency range: 45 - 400 Hz; Overload protection: 600 V; Impedance: 400 kΩ
(*max. 250 V, 3s)
The multimeter may display 5 counts if a measurement input is short-circuited
After using the LoZ feature, leave the multimeter for 1 minute before using it
again
TrueRMS peak (Crest Factor (CF)) ≤3 CF to 600 V
TrueRMS peak for non-sinusoidal signals plus tolerance:
CF >1.0 - 2.0
CF >2.0 - 2.5
CF >2.5 - 3.0
Direct current (A/DC)
6
Range
600.0 µA
6000 µA
60.00 mA
600.0 mA
6.000 A
10.00 A
Overload protection: 600 V
Fuses: µA/mA = 2x 0.55 A/240 V resettable, 1x F2 2.5 A/700 V ceramic, internal
resistance approx. <10 Ω
10 A = High-performance FF 10 A/600 V ceramic fuse
≤ 6 A = continuous measurement, >6 A = max. 30 s at intervals of 15 minutes
The multimeter may display 3 counts when a measurement input is open.
7
94
+ 3%,
+ 5%
+ 7%
Resolution
0.1 µA
1 µA
0.0 1mA
0.1 mA
0.001 A
0.01 A
Accuracy
±(0.9% + 7)
±(1.3% + 4)
±(1.5% + 7)