For the Fitter

2. Installation instructions

2.1 Technical Data

Model
Storage Capacity
Rating
Voltage
Dimensions
Weight ca
Day-acting element
Core-brick packs
1)
adjustable from 815 – 840 mm
2)
with working top

2.2 Heater Positioning and Installation

The electrical installation of this heater must be approved by your local electricity company.
The installation must be carried out by a competent electrician.
Electrical installation and local safety regulations must also be adhered to.
If heaters are to be installed in commercial or public buildings such as hotels, holiday homes or
apartments, schools, administrative buildings etc., a special warning label is to be attached to the
top of the heater. This label is available from your local contractor.

2.2.1 Procedures to be followed

All National and Local Safety Codes should be adhered to both at the planning and installation
stages.

2.2.2 Choosing the Heater Position

The Kitchen Heater can either be integrated into any fitted kitchen unit or, using the special
accessory set, be installed as a free-standing unit.
The floor must be able to take the weight of the heater. Please, therefore, note carefully the
weight given in the Technical Data section (see section 2.1) of this instruction. If in doubt, consult
a building engineer or architect.
AEG storage heaters generally need no protective underboard when standing on normal flooring,
as long as this is flat and smooth and can withstand temperatures of 80°C minimum.
In the case of soft, load-sensitive or non-heat-resistant floors or carpeting, as well as to even out
any surfaces, it is advisable to first put down a protective board the size of the underside of the
heater. When using high- or thick-pile carpeting a protective board or floor-standing consoles
should definitely be used.

2.2.3 Regulations governing heater position

Due to the low surface temperatures of the side panels, the storage heater can be positioned
directly beside any other integrated appliance in a fitted kitchen.
It is not advisable, however, to place the heater next to a refrigerator or deep-freeze due to
energy-saving considerations. The heater can be placed flush to the rear wall.
The warm air outlet and the cold air inlet must be keep free at all times. Any objects must be
placed at least 30cm from the air grilles.
26
WSP 300 H
24 kWh
3.0 kW
3/N/PE ~ 400 V, 1/N/PE ~ 230 V
1)
Height:
820 mm
/ 850 mm
Width:
445 mm / 450 mm
Depth:
570 mm / 600 mm
184 kg
0.5 kW
8 x SP28
2)
2)
2)

Quicklinks ausblenden: