794 Basic Titrino
.P
PowerOn: Simulation of power on (3.2.2.99). Not from mains.
Messages from node .T, Titrator:
.T.R
Ready: Status 'Ready' has been reached.
.T.G
Go: Instrument has been started.
.T.GC
GoCommand: Instrument (or submethod in TIP) has received a go
command.
.T.S
Stop: Status 'Stop' has been reached.
.T.B
Begin of sequence (or submethod).
.T.F
Final: End of determination (or submethod), the final steps will be
carried out.
.T.E
Error. Message together with error number, see page 82ff.
.T.H
Hold: Status 'Hold' has been reached.
.T.C
Continue: Continue after hold.
.T.O
Conditioning OK: EP reached (in SET with conditioning).
.T.N
Conditioning Not OK: EP not reached (in SET with conditioning).
.T.Re
Request: In the inquiry of an identification or the sample size after
start of titration.
.T.Si
SiloEmpty: Silo empty, i.e. the last line has been removed from
the silo memory.
.T.M
MeasList: Entry in the measuring point list (with DET, MET).
.T.EP
EPList: Entry into EP list (with DET, MET, SET)
.T.RC
Results have been recalculated.
Messages for changings in the I/O lines. If the changings are made simulta-
neously, there is 1 message. Pulses receive 2 messages: one message each
for line active and inactive.
.I
Input: Change of an input line.
.O
Output: Change of an output line (except 7, pin 2, for recorder
pulses).
If a change occurs that requires a message, the Titrino sends space (ASCII
32) and ! as an introducer. This is followed by the name of the device (see
3.2.2.55). Special ASCII characters in the device name are ignored. If no de-
vice name has been entered, only ! is sent. Finally the Titrino sends the infor-
mation which node has triggered the message.
Example: !John".T.Si": The message was triggered from instrument "John",
node .T.Si
3.2.2.98. Setup.Graphics.Grid
Setup.Graphics.Frame
Setup.Graphics.Scale
Setup.Graphics.Recorder.Right
Setup.Graphics.Recorder.Feed
Change in the appearance and the format of the curve for the output. The set-
tings are valid for both Titrino COM ports.
.Grid:
On/off switching of grid over curve.
.Frame:
On/off switching of frame surrounding the curve. If grid and frame
are switched off, the curve is printed faster as the print head does
not have to move to the end of the paper.
.Scale:
Type of scaling of the measured value axis: Full means that the
scale runs from the smallest up to the greatest measured point.
With auto, the smallest measured value is taken and the next
smaller tick defines the beginning of the scale; the next greater
tick to the greatest measured value is the end of the scale.
3.2 Remote control commands
0.2...0.5...1.00
0.01...0.05...1.00
ON, OFF
ON, OFF
Full, Auto
123