1. To switch on, press the "I" On switch
and the device starts up (see
2. To switch off, press the "0" off switch and
the device switches off (see
After switching on the device, wait until the
device has reached its max. speed. Only
then must you start with the grinding.
The disc will continue to
run after the equipment is
switched off. There is a risk
of injury.
Test run:
Before starting work and after each
change of grinding disc, carry out a test
run of at least 60 seconds with no load.
Switch off the equipment immediately if the
disc runs lumpy, substantial vibrations oc-
cur, or abnormal noises are generated.
Grinding with the grinding
disc
Fold down the spark protector (1)
when grinding in order to avoid
injury from sparks.
The arrow on the protective hood
(
5) shows the direction of rota-
tion of the grinding disc.
• Place the workpiece on the workpiece
support (
11) and slowly bring it to
its desired angle on the grinding disc
(
10).
• Move the workpiece slightly from side
to side in order to achieve an optimal
grinding result. This way, the grinding
disc is worn uniformly. Occasionally,
allow the workpiece to cool down.

Change grinding disc

14a).
14b).
GB
IE
Information on replace-
ment:
• Never operate the device without
protective equipment.
• Ensure that the rotation speed
stated on the grinding disc
(
10) is the same or higher
than the nominal rotation speed
of the device.
• Ensure that the grinding disc
dimensions match those of the
device.
• Only use fl awless grinding discs
(sound test: an undamaged grind-
ing disc hanging freely on a string
will result in a clear sound if it is
tapped with a plastic hammer).
• Never re-drill a locating hole
which is too small to make it
larger.
• Never use separate bushings or
adapters in order to make grind-
ing discs whose hole is too large
fi t the device.
• Do not use any saw blades.
• To clamp the grinding tools only
use the clamping fl ange provid-
ed. The pads between the clamp-
ing fl ange and the grinding tools
must be made of elastic materials
e.g., rubber, soft cardboard etc.
• Always reassemble the device
completely after replacing the
grinding disc.
Switch the device off and remove
the mains plug.
Allow the device to cool down.
Wear protective gloves when
changing the grinding discs in or-
der to avoid cutting damages.