19
UP
DOWN
MENU
Press the MENU button
for 1 second to display the
parameter in order to save
the modified value, or MENU
quickly to quit the function
without saving.
PARAMETERS
TCL
1
Automatic reclosure time (0 = off)
Reclosing time after transit on PH1
ttr
2
(0 = off)
Sensitivity on obstacles
SEI
3
0 = Maximum impact force
10 = Minimum impact force
Motor speed during opening
1 = minimum
2 = low
SFO
4
3 = medium
4 = high
5 = maximum
Motor speed during opening deceleration phase
1 = minimum *
2 = low *
SSO
5
3 = medium
4 = high
5 = maximum
Motor speed during closing
1 = minimum
2 = low
SFC
6
3 = medium
4 = high
5 = maximum
Motor speed during closing deceleration phase
1 = minimum *
2 = low *
SSC
7
3 = medium
4 = high
5 = maximum
STEP BY STEP or SBS configuration:
0 = Normal (AP-ST-CH-ST-AP-ST...)
1 = Alternate STOP (AP-ST-CH-AP-ST-CH...)
SBS
8
2 = Alternate (AP-CH-AP-CH...)
3 = Apartment block – timer
4 = Apartment block with immediate reclosure
Additional stop input:
0 = disabled
sT2
9
1 = The PAR input becomes the STOP function. NO
contact input
Deceleration distance
LSI
10
0 to 100 = Motor deceleration percentage during
opening and closure
Post blackout procedure
BlT
11
0 = No action, remains stationery
1 = Closure
Energy saving: enables photocell switch-off when
gate is closed
SBY
12
0= disabled
1= enabled
* = only for SUN4224/SC4224
** = for SUN4224/SC4224 min 15
*** = The default value for barriers is 4
tCL
UP
DOWN
MENU
Press the + and – buttons to
scroll through the functions to
modify other parameters.
DESCRIPTION
--
UP
DOWN
MENU
Press the MENU button quickly
to quit the menu.
DEFAULT
0
0
3
4
1
4
1
0 ***
0
20
0
0
MIN
MAX
UNIT
0
900
s
0
30
s
0
10
1
5
1
5
1
5
1
5
0
4
0
1
0 **
100
%
0
1
s
0
1
EN
27