Storage temperature
Dust and water spray protection (except battery compartment)
Tripod thread
Dimensions length x width x height
Weight with foot and including batteries
5
Operation
5.1
Inserting/changing batteries
•
Make sure that battery polarity is correct.
•
Changes all the batteries at the same time.
•
Use only batteries that have been manufactured in accordance with international standards.
1. Flip the battery compartment open.
2. Remove the spent batteries, if applicable.
3. Insert the new batteries.
4. Close the battery compartment.
5.2
Fall arrest
WARNING
Risk of injury by falling tool and/or accessory!
▶ Use only the Hilti anti-fall cable recommended for your product.
▶ Prior to each use, always check the anti-fall cable and the attachment points of the anti-fall cable for
possible damage.
Comply with the national regulations for working at heights.
As drop arrester for this product, use only the Hilti PMA 92 anti-fall cable.
▶ Secure the anti-fall cable to the laser and to a load-bearing structure. Check that it holds securely.
Comply with the operating instructions of the Hilti anti-fall cable.
5.3
Switching the laser beams on
1. Set the selector switch to the
▶ All laser lines and all points are switched on.
2. Press the line mode button repeatedly until the desired line mode is set.
▶ The product repeatedly cycles through the operating modes in the following sequence: all lines,
horizontal line, vertical line.
5.4
Setting the laser beam for the "Inclined line" function
1. Set the selector switch to the
▶ The horizontal line is switched on.
18
English
2
position (ON / unlocked).
position (ON / locked).
−25 ℃ ... 63 ℃
(−13 ℉ ... 145 ℉)
IP 54 in accordance
with IEC 60529
UNC 1/4"
66 mm x 116 mm x
103 mm
(2.6 in x 4.6 in x 4.1 in)
600 g
(21.2 oz)
2341494
*2341494*