For remote controller
1. Remove cover of remote controller by sliding down and take it out.
2. If batteries are exist, please take them out. The combination of using
wire controller and batteries may cause of batteries explosion.
3. Make hole for insert control wire by use screwdriver break the plastic for
cover hole as shown on fi gure 4.
4. Insert control wire from rear side of remote controller as shown on
fi gure 5.
5. Fix control wire which arrange as shown on fi gure 6 and 7 to terminal
by provided screws (tighten fi rmly but not over 0.25 N·m (0.03 kgf·m)).
6. Set control wire through gutter way at rear side of remote controller as
shown on fi gure 8.
7. Fix provided screw (Ø3.1×16L) on the wall to hang remote controller as
shown on fi gure 9.
8. Mark and arrange hole for fi x below screw (Ø3.1×25L) as shown on
fi gure 9.
9. Assembly battery cover which provided with accessory bag then use
provide screw (Ø3.1×25L) to fi x battery cover together with wall as
shown on fi gure ! (tighten fi rmly but not over 0.15 N·m (0.02 kgf·m)).
10. Reassembly cover of remote controller.
4
1.5V
1.5V
Plastic for cover hole
7
Control wire
Terminal
Wire and hole for fi x screw should be
have space to prevent wire damage
during close by battery cover
Hole for hang
remote controller
Control wire
Remote controller
Remote controller
8
Battery cover
5
6
30 mm
5 mm
20 mm
* Wire size 28-22AWG
Control wire
or 0.08-0.32 mm
Outer diameter not over 4.7 mm,
control wire length 30 m. or less.
1.5V
1.5V
Wall
Screw (Ø3.1×25L)
for fi x battery cover
!
Screw
Tighten fi rmly but not over
0.15 N·m (0.02 kgf·m)
*Remark : 1. Recommend to use double insulation lead wire for connect
Piping and Drain Hose Installation
Piping and drain hose forming
* Since dewing results in a machine trouble, make sure to insulate both
connecting pipes. (Use polyethylene foam as insulating material.)
Rear right
Rear left
Bottom left
Left
Bottom right
Right
1. Die-cutting back body slit
Cut out the slit on the left or right side of the back body for the left or right
2
connection and the slit on the bottom left or right side of the back body
for the bottom left or right connection with a pair of nippers.
2. Changing drain hose
For leftward connection, bottom-leftward connection and rear leftward
connection's piping, it is necessary to change the drain hose and drain
cap.
How to remove the drain hose
• The drain hose can be removed by removing the
screw securing the drain hose and then pulling out
the drain hose.
• When removing the drain hose, be careful of any
sharp edges of steel plate. The edges can injuries.
• To install the drain hose, insert the drain hose
fi rmly until the connection part contacts with heat
insulator, and then secure it with original screw.
Control wire
Screw (Ø3.1×16L)
How to remove the drain cap
for hang remote
Clip the drain cap by needle-nose
controller
pliers and pull out.
How to fi x the drain cap
1) Insert hexagon wrench (4 mm)
in a center head.
2) Firmly insert the drain cap.
Do not apply lubricating oil
(refrigerant machine oil)
when inserting the drain
cap. Application causes
deterioration and drain
leakage of the plug.
9
CAUTION
Firmly insert the drain hose and drain cap; otherwise, water may leak.
9
remote control and air conditioner.
2. For wire operation, 1 remote control can control only 1 indoor
unit.
3. In wire operation, remote controller will return to initial
condition (PRESET, TIMER and CLOCK will return to
initial condition) when user shutdown power supply of air
conditioner.
No gap
Drain hose
Insert a hexagon wrench
(4 mm).