MAINTENANCE DIAGRAM
1
General
The user can carry out only those actions for which in this book authorisation
are given. Each other act has been prohibited! For the maintenance turns of
burner kettle, high pressure pump, combustion engines and of components
which have to do with the security, one must contact our DiBO technicians.
2

Periodic maintenance

DESCRIPTION
Control of the electric cables, high and low pressure
hoses and coupling and control of the oil level.
Refreshing pump oil.
Refreshing reduction gearbox oil.
Cleaning water filter.
All following refreshments of pump oil / reduction
Maintenance engine.
Extra control/replacement of joints, valves, o- rings
by acknowledged DiBO- technicians!
3

Control/refreshing of oil level and pump oil

Check for each use of the machine the oil with the oil level glass or with the oil
level bar. Oil must stand right with the sign of the oil level glass, if the this case
is not, oil tops up until the sign. If oil looks forward to there milky, consult directly
the DiBO technicians. To refresh oil, follow procedure below:
• Unbolt the drain plug below the pump.
• Unbolt the tap with the oil level bar.
• Catch all oil in a barge and remove oil like further described in the guide.
• Force up the drain plug there and top up the oil in the breach to the upper
part to on the mark line.
• Force up the tap with the oil level bar there.
• Recommended oil: 1.836.042.
4

Control/refreshing the reduction oil - oil level

Check for each use the machine the oil with the oil level glass. Oil must stand
right with the sign of the oil level glass, if the this case is not, oil tops up until the
sign. If oil looks forward to there milky, consult directly the DiBO technicians.
To refresh oil, follow procedure below:
• Unbolt the drain plug below the reduction gearbox.
• Catch all oil in a barge and remove oil like further described in the guide.
• Force up the drain plug there and top up the oil in the breach to the upper
part to on the mark line.
• Recommended oil: 1.836.015.
5

Maintenance petrol motor

For maintenance activities to the petrol motor we guess to consult the supplied
instructions for use of the motor. Recommended oil: 1.836.010.
6
Cleaning of the water filters
Clean the water filters regular and remove possible dirt.
DiBO 20
gearbox oil.
PERIOD
After each use.
First 50 hours.
First 50 hours.
Each 50 hours/each
month.
Each 400 hours/
yearly.
See enclosed motor
instruction manual.
Pay attention, shorter
maintenance inter-
vention necessary to
the motor!
Each 600 hours.