Operation with DiagMonitor monitoring software
Installing DiagMonitor
If your device uses the "A1 image" (see "Scope of delivery of the software (Page 18)"), you can install the DiagMonitor
monitoring software as follows.
Procedure
1. Insert the Restore USB stick into your device.
2. Navigate to the "Additional_Products" folder and open the version-specific DiagMonitor folder.
3. Run the following files:
DiagMonitor_Silent_Install.bat
–
CM_Activate.exe
–
The DiagMonitor monitoring software is installed.
4. Reboot the computer.
5. Configure the SNMP service. You will find information on this in the section: "Configuring SNMP service (Page 26)".
6. Now configure the monitoring functions of DiagMonitor. You will find information on this in the section: "Configuring
monitoring functions (Page 26)".
Configuring SNMP service
SNMP service is installed on your computer. It is preset in such a way that SNMP packets are accepted from any host. You can
change this setting.
Procedure
1. Select "Computer Management > Services and Applications > Services".
2. Double-click "SNMP Service'".
The "Properties" windows opens.
3. Select the "Security" tab.
4. Select one of the following options:
Accept SNMP packets from any host
–
No further settings are required here.
Accept SNMP packets from these hosts
–
For the station to be monitored, enter the local address or the local computer name and the address of the
maintenance server (both addresses for a redundant MS server).
On the Maintenance Station, enter the local address or local computer name.
5. Under "Accepted community names", enter the name used in the configuration with read/write permissions.
6. Confirm your entries.
Configuring monitoring functions
Perform the configuration of the monitoring functions for all the monitored stations.
Requirement
You have started the SIMATIC IPC DiagMonitor Management Explorer with administrator rights.
1. Select "Start > SIMATIC DiagMonitor > Management Explorer".
2. Select the menu command "Station > Add...".
3. Select the "Local station" for which you want to monitor certain events.
4. Configure the desired events, for example, cyclic operating hour interrupts.
5. Confirm your entries.
26
SIMATIC IPC647E/847E
A5E51584613-AA , 01/2022