Herunterladen Inhalt Inhalt Diese Seite drucken

LORCH MicorStick 180 ControlPro Bedienungshandbuch Seite 39

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Messages
Code
Fault
E18-00 Overload protection
E22-00 Primary undervoltage Internal operating voltage too
E22-03
E22-04
E25-00 Voltage Reduction
Device (VRD)
E25-01
E30-01 Configuration
E30-03
E30-04
E31-01 Communication
E31-03
E31-04
E31-05
E31-06
E32-00
Power module (FPGA) Internal processor fault
to
E32-05
E34-01 Fan
E49-01 Battery
E49-02
Tab. 4:
Notes and fault messages
07.19
Possible cause
Safety switch device to protect
electrical components
low
VRD defective or short circuit
between work piece and torch.
Configuration or operating
panel recognition faulty
Internal communication faulty
Fan current too low
Battery charging level low
Communication battery
909.4119.9-02
Rectification
Allow the equipment to cool down
in standby mode. Inform the cus-
tomer service in the event of a re-
peated or permanent fault message
Check mains voltage, test device on
another power socket. Switch the
equipment off and on again. Inform
the customer service in the event
of a repeated or permanent fault
message
Torches and electrode holders must
not have electrical contact to the
ground cable (short circuit) when
switched on.
Switch the equipment off and on
again. Inform the customer service
in the event of a repeated or perma-
nent fault message
Disconnect and re-connect battery.
Recharge battery as required Inform
Customer Service when the fault
persists
- 37 -

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Micorstick 180 rc controlpro

Inhaltsverzeichnis