MALFUNCTION: CAUSES AND SOLUTIONS

12 MALFUNCTION: CAUSES AND SOLUTIONS

MALFUNCTIONS, CAUSES AND SOLUTIONS

Following is a list of some of the inconveniences that may occur when using the machine.
For all problems not included in this table, please contact the Technical Assistance Service.
PROBLEMS
Water is not dispensed by the
group
Water does not heat up
Dispensing does not occur in
regular doses
There is a leak from the steam
wand with the tap closed
Steam is leaking under the tap
knob during opening
Insufficient use of coffee
During dispensing a leakage
occurs between the group and the
filter holder
Autosteamer not working
Cold tea water
Malfunction: causes and solutions
CAUSES
The water mains tap or the impurity
filter taps are closed.
The water intake union filter is
clogged
Clogged Gigleur
Burnt out resistor
Safety thermostat tripped
Defective volumetric dosing device
Defective gasket
Faulty tap axis gasket
The grain size of ground coffee is
not correct (too fine or too coarse
grain)
Partially clogged head and filters
Incorrect service boiler temperature Call the technical service
Defective cup gasket or uneven filter
edge
Wand probe breakage (does not
froth and heat the drink and the
Autosteamer button panel LEDs are
flashing)
Incorrect mixed water setting
84
SOLUTIONS
Open the tap
Disassemble and clean. Check
regeneration of the impurity filter
resins
Call the technical service
Call the technical service
Call the technical service
Call the technical service
Call the technical service
Call the technical service
Check the grinding time and/or adjust
grinding
Call the technical service
Call the technical service
Call the technical service
Set mixed water