BTL _ _ _ _ _ _ - _ _ _ _ -C1...
Magnetostrictive linear position sensor
6
System Functions (continued)
6.6.3
Events
PD Update Timeout
With special process data values, the device automatically
checks whether the values are updated in the time period
specified by the device. If an update timeout is triggered as
a result, this is output via the following diagnosis
messages:
Event
Event
Event –
Code
Type
Description
– Remedy
0x1851
Notifica-
Process Data
(6225)
tion
Update
Timeout – for
information
purposes
only
0x1852
Warning
Multiple
(6226)
Process Data
Update
Timeout – for
information
purposes
only
Tab. 6-18: Process data information and configuration – Events
PD Profile Selection after Change of Variant
If the variant of the device is changed, the currently set
profile is retained.
In the case that the corresponding PD profile is not valid
for this variant, the default profile for the corresponding
variant is selected.
Event
Event
Event –
Code
Type
Description
– Remedy
0x1850
Notifica-
Process data
(6224)
tion
profile
selection
cannot be
used –
default value
is used.
Tab. 6-19: Process data information and configuration – Events
www.balluff.com
PD Invalid
PD Inputs Invalid:
Input data (device-to-master) is marked as invalid if the
device status (see section 6.1 on page 61) of the device
is Failure. In all other states, replacement values for the
data are output for which the content cannot be output
correctly.
Device Status
0 – Device is
operating properly.
0 – Device is
operating properly.
Device Status
0 – Device is
operating properly.
english