Magnetostrictive linear position sensor
3
Overview of IO-Link Data and Functions (continued)
Event Code
Event Type
0x8D10
Warning
(36112)
0x8D12
Warning
(36114)
0x8D13
Warning
(36115)
0x8D20
Warning
(36128)
0x8D22
Warning
(36130)
0x8D23
Error
(36131)
0x8D24
Warning
(36132)
0x8D25
Error
(36133)
Tab. 3-19: Events – Overview
www.balluff.com
Event – Description – Remedy
Device Temperature Upper Warning – The set upper
temperature warning threshold has been exceeded.
The defined threshold of the device-internal humidity
was exceeded.
► Check installation and ambient conditions.
One or more extreme conditions present.
Device Temperature Lower Warning – The device
temperature has fallen below the set lower
temperature warning threshold.
Warning limit for write cycles reached – maintenance
monitoring no longer guaranteed – for information
purposes only.
Write cycle limit reached – saving no longer ensured
– replacement recommended.
Parameter write error – for information purposes
only.
Parameters not consistent – basic settings are used,
service required. Parameterization processes and
resets can no longer be performed.
Device Status
0 – Device is operating properly.
1 – Maintenance-Required
0 – Device is operating properly.
0 – Device is operating properly.
0 – Device is operating properly.
1 – Maintenance-Required
0 – Device is operating properly.
4 – Failure
english
25