Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BIS C-6 0 RS 232 Serie Handbuch Seite 49

Elektronische identifikations-systeme
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

C-6_0-007-00_836905_E_0704.p65
19
Menu Allocate
Input/Outputs
(BIS C-600 only)
(continued)
20
Menu Allocate
Input/Outputs
(BIS C-600 only)
(continued)
20
english
BIS C-600
Configuration
Output Halfbyte of the Data Contents of an Address:
IN/OUTPUT CONFIGURATION
( ) Output not used.
( • ) Output halfbyte of data contents of an address.
( ) Compare contents of multiple addresses with a fixed value.
( ) Compare contents of an address with various fixed values.
( ) Compare contents of multiple addresses with a content of one address.
( ) Output data bits of variable addresses.
( ) Program input as data bit to data carrier.
( ) Read and transmit data carrier data without command.
<
OK
>
< Shortform >
< ESC = Exit >
OUTPUT HALFBYTE OF DATA CONTENTS OF AN ADDRESS
Data carrier adress [ 9999 ]
( ) Output High Nibble ?
( • ) Output Low Nibble ?
< Data to BIS >
< Store >
Either the upper or lower 4 bits (Nibble) of the 8 bits data contents of an address is output
(Bit 0 on Output 1, Bit 1 on Output 2, etc.). The address is given in decimal.
BIS C-600
Configuration
Compare Contents of multiple Addresses with a fixed Value:
The data contents of up to 4 addresses are compared with a fixed decimal value. To each
address can be assigned which of the Outputs 1 to 4 is set or cancelled by a positive result
of the comparison an whether in case of a negative result of the comparison the output shall
not be changed or shall be set in contrary to the definition with the positive result (inverted
response).
All addresses found within the read command will be processed.
Compare Contents of multiple addresses with fixed value
Address
Output
[ 9999 ]
[ 1 ]
[ 9999 ]
[ 2 ]
[ 9999 ]
[ 3 ]
[ 9999 ]
[ 4 ]
< Data to BIS >
< Store >
If the parameter "Process outputs with CT-Present" is included in the initialization, then this
function also will be carried out on recognition of a new data carrier (one or more of the ad-
dresses given should be on the first page of the data carrier).
< Print . . . . >
< ESC = Exit >
Fixed value:
[ 000 ]
Positive compar.
Negative compar.
( • ) Set
( ) No change
( ) Clear
( • ) Invert
( • ) Set
( ) No change
( ) Clear
( • ) Invert
( • ) Set
( ) No change
( ) Clear
( • ) Invert
( • ) Set
( ) No change
( ) Clear
( • ) Invert
< ESC = Exit >
< F1 = Help >
< F1 = Help >
< F1 = Help >
19