Menu settings
BIS C-6_0,
Page Size Field
Menu settings
BIS C-6_0,
Input Field
18
Menu Allocate
Input/Outputs
(BIS C-600 only)
BIS C-600 only
18
english
BIS C-6_0
Configuration
Data carrier memory is organized in page sizes of 32 or 64 bytes (also referred to as block
size). Factory setting: 32 bytes.
32-byte page size
64-byte page size
The digital control input on the BIS C-600 can be specified for the desired function. Factory
setting is Reset.
– Reset
If Reset is selected, a High signal on this input resets the BIS C-600 processor. All pending
commands are deleted.
– Head Select
If Head Select is selected, this input is used to activate the desired read head.
Input Low:
Head 1 selected.
Input High:
Head 2 selected.
-> This function always has priority. For example the function "Both read/write heads active"
selected by the 'HT' command is deactivated.
– Data bit to data carrier
When a new data carrier is recognized, a freely defined bit is written to the data carrier
directly or inverted to a specified address. After a successful write the defined output is set
until the data carrier leaved the acvtive zone of the read/write head.
-> The 'Dynamic Mode' parameter is automatically reset.
– No function
The input is not processed.
BIS C-600
Configuration
Allocate to input/outputs
The outputs can have various functions allocated to them. The output functions are always
processed when reading. The condition for this is that the respective address was read during
the preceding read request.
ALLOCATE INPUT/OUTPUTS
( • ) Outputs not used.
( ) Output half-byte of the data contents of an address.
( ) Compare contents of mjltiple addresses with a reference value.
( ) Compare contents of one address with various reference values.
( ) Compare contents of multiple addresses with the contents of another address.
( ) Output data bits from variable addresses.
( ) Program input as data bit to data carrier.
( ) Read and send data carrier data without direct command.
<
OK
>
< Shortform>
< ESC >
"Outputs not used" deactivates processing of the outputs.
"Data to BIS" sends the data to the processor. "Save" stores the data in the configuration file
of your computer.
BIS C-1_ _-02, -03, -04, -05
BIS C-1_ _-10, -11, -30, -32
english
< Print. . . . >
< F1 = Help >
17