Herunterladen Inhalt Inhalt Diese Seite drucken

Planning Advice; Minimum Distances (Safety Gaps) - EOS Vitae Protect Compact Montage- Und Gebrauchsanweisungen

Infrarotwärmestrahler
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Caution!
If the connection cable of this appliance be-
comes damaged, it must be replaced by a
special connection cable which can be ob-
tained from the manufacturer or customer
service department.
Important note!
Do not expose the radiator to mechanical
loads (shocks, pressure). Risk of breakage!

Planning advice

The emitters should be arranged so that the
user is heated from as many directions as possi-
ble for a possibly even heat treatment.
An example given in the Fig. 3 shows the instal-
lation in four corners by a single person cabin.
Depending on the cabin size and layout the po-
sition of radiators may vary.
Looking into the spotlight for too
long can cause eye damage. In this case,
wear suitable safety goggles.
The distance between the emitter and body
surface depends on the power output.
By Vitae 750 W the recommended distance to
the user should be ca. 50 cm.
Also by other versions (350 - 500 W) the distance
should not be less than 15 cm.
Vitae emitters feature a very powerfuly heat
intensity. A too small can quickly lead to an
unpleasant overheating.
22
The sufficient gap increases furthermore the
effective heat coverage and contributes to a
more pleasurable heat experience.
The intensity of Vitae emitters can be quick-
ly adjusted using an optionally available
wall-mounting IR dimmer (item 4954), which
can be mounted inside IR cabin.
Please notice that every person feels heat in a
different way, the distance to the emitter may
therefore vary.

Minimum distances (safety gaps)

The minimum distance from the emitter upper
edge to the booth ceiling must be 7 cm.
Minimum gap from the radiator's bottom edge
by vertical mounting must be at least 4 cm. See
fig. 4
The horizontal minimum distance between the
emitter and all combustible parts must be 4 cm
(Fig. 6).
Make sure to provide sufficient ventilation
behind and around the radiator.
min. 7 cm
min. 4 cm
Fig. 3
min. 4 cm
ATTENTION!
When installing the IR radiator, be sure that the cable
connector is at the bottom.
EN
Fig. 4
min. 4 cm
Kabelanschluss
muss unten sein
Cable connection
downwards

Werbung