Installation / Preparation for Commissioning
4 Installation / Preparation for Commissioning
The measuring system with INTERBUS-S interface is designed as a remote bus
module. This makes it easy to integrate in the bus ring in the same way as a
PHOENIX-CONTACT bus terminal. To ensure that the protocol meets INTERBUS-S
requirements, an SUPI (serial microprocessor interface) is integrated in the measuring
system. The SUPI is an INTERBUS-S protocol chip developed by PHOENIX-
CONTACT which carries out the following functions:
BUS interfacing: Directions of reception and transmission
CRC check
Preset
Transfer protocol
etc.
The measuring system supports AIO profile class. This can be recognized by the
device ID and the input and output data width with which the measuring system logs
on to the INTERBUS.
Profile
AIO
4.1 Set zero shift
Triggering the preset button on the bus cover, sets the current measuring system
position value to a customer-specific preset value.
TR-Electronic GmbH 2021, All Rights Reserved
Page 18 of 20
Device-ID
51, 0x33
Risk of injury and damage to property by an actual value jump when the
zero shift is set!
The preset adjustment function should only be performed when the
measuring system is at rest, otherwise the resulting actual value jump must
be permitted in the program and application!
TR-ECE-BA-DGB-0167 v01
Data format
2 WORD INPUT/OUTPUT
Printed in the Federal Republic of Germany
03/16/2022