FAMILY
PARAMETERS
Lower Wobbe index (at 15°C-1013 mbar)
Net Calorific Value
Supply nominal pressure
Supply minimum pressure
PARAMETERS
Burner: diameter/length
Diaphragm: number and diameter holes
CH maximum gas capacity
DHW maximum gas capacity
CH minimum gas capacity
DHW minimum gas capacity
Number of fan rotations with slow ignition
Maximum number of CH fan rotations
Maximum number of DHW fan rotations
Minimum number of CH/DHW fan rotations
Max n° of DHW fan rotations in C(10) configuration (Ø60-100 ● Ø80-125 ● Ø80)
Max n° of DHW fan rotations in C(10) configuration (Ø60-100)
Max n° of DHW fan rotations in C(10) configuration (Ø80-125 ● Ø80)
Min n° of CH/DHW fan rotations in C(10) configuration (Ø60-100 ● Ø80-125 ● Ø80)
Min n° of CH/DHW fan rotations in C(10) configuration (Ø60-100)
Min n° of CH/DHW fan rotations in C(10) configuration (Ø80-125 ● Ø80)
b
DHW functions refer only if a water tank is connected (accessory available on request)
15 ErP DATA
Parameter
Seasonal space heating energy efficiency class
Water heating energy efficiency class
Rated heat output
Seasonal space heating energy efficiency
Useful heat output
At rated heat output and high-temperature regime (*)
At 30% of rated heat output and low-temperature regime (**)
Useful efficiency
At rated heat output and high-temperature regime (*)
At 30% of rated heat output and low-temperature regime (**)
Auxiliary electricity consumption
At full load
At part load
In Stand-by mode
Other parameters
Stand-by heat loss
Pilot flame energy consumption
Annual energy consumption
Sound power level, indoors
Emissions of nitrogen oxides
For combination heaters
Declared load profile
Water heating energy efficiency
Daily electricity consumption
Daily fuel consumption
Annual electricity consumption
Annual fuel consumption
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet).
NOTE (if connected to the boiler the external probe or OT remote control or both devices):
With reference to Delegated Regulation (EU) No. 811/2013, the data in the table can be used for completing the product card and the labelling for ambient heating appliances, for mixed
heating appliances, for assemblies of appliances for ambient heating, and for temperature control devices and solar devices:
ADDED DEVICE
EXTERNAL PROBE
OT CONTROL PANEL* (°)
EXTERNAL PROBE + OT CONTROL PANEL*
(*) Set as room thermostat - (°) Factory supplied configuration
28
UM
MJ/m³S
45,67
MJ/m³S
34,02
mbar (mm H2O)
20 (203,9)
mbar (mm H2O)
10 (102,0)
25 IS
G20
mm
70/86
70/86
n° - mm
1 - 4,3
1 - 4,3
Sm³/h
2,12
kg/h
-
Sm³/h
2,64
kg/h
-
Sm³/h
0,38
kg/h
-
Sm³/h
0,38
kg/h
-
rpm
5.500
5.500
rpm
6.200
6.000
rpm
7.600
7.400
rpm
1.600
2.000
rpm
7.600
rpm
-
rpm
-
rpm
1.600
rpm
-
rpm
-
Symbol
FAMILY
-
-
Pnominal
ηs
P4
P1
η4
η1
elmax
elmin
PSB
Pstby
Pign
QHE
LWA
NOx
ηwh
Qelec
Qfuel
AEC
AFC
Class
II
V
VI
FAMILY
G20
37 (377,3)
35 IS
G31
G20
G31
70/125
70/125
1 - 5,2
1 - 5,2
-
3,38
-
1,55
-
2,48
-
3,66
-
1,94
-
2,69
-
0,52
-
0,39
-
0,54
-
0,52
-
0,39
-
0,54
5.500
5.500
7.300
7.200
7.800
7.800
1.700
1.900
-
-
-
-
8.200
-
-
7.800
-
-
-
-
-
1.800
-
-
1.700
-
FAMILY
Unit
25 IS
35 IS
A
A
-
-
20
31
93
94
19,5
31,2
6,5
10,5
87,8
87,9
98,3
98,6
27,0
49,0
13,0
13,0
3,0
3,0
30,2
26,0
-
-
60
96
50
54
46
38
mg/kWh
-
-
-
-
-
-
kWh
-
-
kWh
-
-
kWh
-
-
Bonus
2%
3%
4%
G31
70,69
88
-
-
-
kW
%
kW
kW
%
%
W
W
W
W
W
GJ
dB
%
GJ