WARNING:
Failure to use the mounting fixtures may lead to a
risk of electric shock.
CAUTION:
Before mounting, check that the wall has enough
loading capacity to bear the cooker hood.
When drilling the holes in the wall always make
sure that no existing electrical cables or other ob-
jects are damaged.
Make sure that the ventilation slots are clear of
obstacles and are not covered.
NOTE: Recommendations for preparation work
When installing, ask another person to assist.
Wear protective gloves to prevent injuries from
any sharp edges.
Drilling dimensions
Fig. 1
Fig. 3
Unit mm
Fig. 2
Fig. 4
Fig. 5
Determine the position of the cooker hood central-
ly above the cooking area in accordance with the
specified safety distances.
Totally 6x mounting holes with a diameter of approx.
8 mm are necessary for the wall mounting. Insert the
(Fig. 1).
supplied dowels
First, drill the holes for attaching the housing ac-
cording to the enclosed drilling template. Check
the markings with a spirit level first!
Turn in the upper screws 2x ST4*30mm for the
-
suspension of the housing so far that they pro-
ject approx. 5 mm out of the wall.
Fasten the bracket for the upper shaft termination
with the screws 2x ST4*40mm; after determining
the extension length of the shaft cover.
For extraction mode:
(supplied) with an inner diameter of 150 mm onto the
connecting piece (extraction duct)
Secure the hose with a zip tie.
Hang up the housing. Check the secure hold and
the horizontal position
For extraction mode:
the exhaust hose and connect it with the outlet open-
ing.
Put on the telescoped shaft unit and tighten the
lower screws 2x ST4*30mm through the housing
(Fig. 4)
to secure it
Pull up the inner shaft and fix the shaft cover lat-
erally to the shaft closure bracket using self-
tapping screws 2x ST4*8mm
19
Attach a flexible exhaust hose
(Fig. 2).
(Fig. 3)
.
Check the correct position of
.
(Fig. 5)
.