End-day cleaning

At the end of a work day, unplug the machine from the power mains.
Thoroughly clean the machine using neutral detergents.
Wipe the machine outer parts with a damp sponge.
Do not use steel wool or abrasive cleaning products.
Removal of the removable parts mod."CN"
Lift the head by rotating anti-clockwise the hand lever (mod.CNS-FN).
INFORMATION: Before every operating cycle always check that the removable parts
are well locked to the machine. Lock the pan by rotating anti-clockwise the lower flange.

Long periods of inactivity

If the machine is to be left idle for long periods of time, turn off the main wall switch, thoroughly clean the
machine and cover it with a sheet to protect it from dust.

Foreword

In the event of breakdowns or malfunctioning, turn off the main wall switch and contact your local Dealer's
After-sales service. Do not disassemble any internal machine parts.
The Manufacturer declines all responsability for any tampering !

Troubles, causes and remedies

Trouble
The machine will not start
For removing the pan rotate the lower
flange clockwise and lift the pan upwards

TROUBLESHOOTING

Cause
Main switch is off
No voltage input to power line
Logic board protective fuse is blown
9
OPERATION AND
CLEANING
(mod.CNS).
Turn the main switch on to "I"
Apply to your local Dealer's After-sale service
Apply to your local Dealer's After-sale service
3
4
Remedy

Werbung