8.10.2 Synchronisation with an external
twilight switch
To synchronise the illuminators and camera with an
external light sensitive switch you need to:
• Connect the twilight switch to the terminals: AL1/
AGND (8.4.3 Connection of the alarm inputs, of the
twilight switch and of the relays, page 22).
• Adjust the left illuminator (MASTER):
• Lighting threshold: Set the value to OFF (
8.10.5 LED illuminator switching on threshold
adjustment, page 28).
• Infrared power: Set the value as needed (8.10.6
LED illuminator power adjustment, page 28).
• Adjustment of the the illuminator on the right
(SLAVE):
• Lighting threshold: Set the value to the
maximum (8.10.5 LED illuminator switching on
threshold adjustment, page 28).
• Infrared power: Set the value to the minimum (
8.10.6 LED illuminator power adjustment, page 
28).
From the IR Probe entry select the External option (
10.1.13 Camera Parameters, page 38).
On the I/O digital board, set the values in the
following manner: (10.1.11 Digital I/O, page 37):
• Alarm ID: 1
• Type: NORMALLY OPEN
• Action: IR_FILT
8.10.3 Synchronising the unit with the
LED illuminators
To synchronise the unit with the LED illuminators it is
necessary to:
• Adjust the left illuminator (MASTER):
• Lighting threshold: Set the value as needed (
8.10.5 LED illuminator switching on threshold
adjustment, page 28).
• Infrared power: Set the value as needed (8.10.6
LED illuminator power adjustment, page 28).
MNVCUPTPLUS3_1511_EN
• Adjustment of the the illuminator on the right
(SLAVE):
• Lighting threshold: Set the value to the
maximum (8.10.5 LED illuminator switching on
threshold adjustment, page 28).
• Infrared power: Set the value to the minimum (
8.10.6 LED illuminator power adjustment, page 
28).
From the Camera Parameters entry select the Internal
option (10.1.13 Camera Parameters, page 38).
8.10.4 Manually activate the LED
illuminators
To turn on the LED illuminators:
• Adjust the left illuminator (MASTER):
• Lighting threshold: Set the value to OFF (
8.10.5 LED illuminator switching on threshold
adjustment, page 28).
• Infrared power: Set the value as needed (8.10.6
LED illuminator power adjustment, page 28).
• Adjustment of the the illuminator on the right
(SLAVE):
• Lighting threshold: Set the value to the
maximum (8.10.5 LED illuminator switching on
threshold adjustment, page 28).
• Infrared power: Set the value to the minimum (
8.10.6 LED illuminator power adjustment, page 
28).
27