7.4 Configuration

Before powering the device it must be configured
correctly by setting the dip-switches inside the
configuration window. Open the window by undoing
the screws as shown in the illustration:
Fig. 36

7.4.1 Dip-switch configuration

The following diagram represents the position of
the dip-switches when the configuration window is
opened.
j
When the dip-switch rocker is up it
represents the value 1 (ON) while if it is
down it represents the value 0 (OFF). This
rule is valid for all dip-switches except for
in the section "7.4.6 Serial terminations/
connections", page 23 where they are
inverted.
Rocker up = ON = 1
Rocker down = OFF = 0
Rocker up = OFF = 0
Rocker down = ON = 1
Fig. 37
Baudrate
Protocol Serial and Address
Termination of
RS485 lines
Fig. 38
RS232 serial
connector

7.4.2 Setting the baud rate

Dip-switches 4, 3 and 2 are used to set the
communication rate of the device according to the
table below.
Dip-switch number 1 is used to update the firmware.
During normal use, make sure the rocker is OFF
(DIP1=OFF).
j
When the dip-switch rocker is up it
represents the value 1 (ON) while if it is
down it represents the value 0 (OFF).
BAUDRATE SETTING
Description
DIP
4
Baudrate
OFF OFF OFF
adjustment
ON OFF OFF
OFF ON OFF
ON
OFF OFF ON
ON OFF ON
OFF ON
ON
Firmware update
-
-
Tab. 08

7.4.3 Setting the protocol

Video positioning systems with the ULISSE line can be
controlled by a range of protocols.
j
When the dip-switch rocker is up it
represents the value 1 (ON) while if it is
down it represents the value 0 (OFF).
PROTOCOL SETTING
DIP
DIP
8
7
MACRO
OFF OFF OFF OFF OFF ON
(VIDEOTEC)
PANASONIC
OFF OFF OFF ON OFF ON
PELCO D
OFF OFF OFF OFF ON
AMERICAN
OFF OFF OFF OFF ON
DYNAMICS
VISTA
OFF OFF OFF ON
Tab. 09
DIP
DIP
DIP
Configuration
3
2
1
-
300 baud
-
600 baud
-
1200 baud
ON OFF
-
2400 baud
-
4800 baud
-
9600 baud
ON
-
19200 baud
ON
ON
-
38400 baud
-
-
ON
Set up enabled
-
-
OFF
Set up disabled
DIP
DIP
DIP
DIP
DIP
6
5
4
3
ON
OFF OFF
OFF OFF ON
ON
ON
OFF OFF ON
DIP
2
1
ON
OFF
ON
21