Vacuum Hose Lifter Components
Lifting hose unit with Operating Valve Unit
5

Operating

5.1 Safety
Instructions
Danger
5.2 Lifting, Lowering
and Landing
Loads
Danger
Lifting
Attention
Local safety requirements are fully applicable. The following safety instructions are
complimentary to the rules in force and do not supersede the latter:
Wear safety shoes.
Before transporting dangerous goods the corresponding safety clothes
have to be put on.
Never exceed the maximum lifting capacity of the lifting device.
Observe the name plate on the handle.
Do not stand below the load. Always keep clear of the load.
Never carry people or animals with the load or the lifting device itself !
Operate only when you can view the entire working area.
Look out for other persons in the working area.
Never manoeuvre loads above people.
Never lean about lifted loads.
Do not let go of the handle whilst lifting a load.
Do not pull loads to the side or drag them along with the lifting device.
Do not rip loose loads that have become jammed.
If there is a power failure immediately turn the handle (J
upwards the regulator lever (J
from dropping off. The reserve vacuum will let the lifting device lower slowly with
the load.
Apply suction and lift only to appropriate loads (check for stability and porosity).
The lifting device is mounted into the crane rails with rail end stops.
While moving against the rail end stops, strong horizontal forces can occur.
These forces can result in releasing the load.
If the lifting unit (lifting tube) is not able to lift the vacuum-gripped load, never
try to support the lifting of the load, it is possible that the gripper's holding
force is inadequate.
The load could fall  risk of injury.
The following operating steps must be checked by a qualified mechanic prior to use
of the device by the operating personnel. Correct faults before start-up.
The hovering position (without load) must be adjusted prior to start up, see 4.2.
Place the vacuum head directly above the load.
Press the regulator lever (1) down. The lifting tube descends and the vacuum
head lowers.
Apply the vacuum head to the load. Distribute load evenly.
Slowly push the regulator lever (1) upward. The device attaches to the load.
Attention: the regulator lever must not be on the position "Lift"
for more than 90 seconds because otherwise:
the blower could be damaged and fail,
all guarantee claims are void!
power is wasted unnecessarily.