Herunterladen Inhalt Inhalt Diese Seite drucken

stayer SC241W Bedienungsanleitung Seite 40

Vorschau ausblenden Andere Handbücher für SC241W:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 50
Adjusting
1.Loosen fastening screw 35.
2.Lower the head down to the lower stop by means
of 4.
3.Tighten or loosen screw 36 until button 31
smoothly penetrates until abutting. Whilst
retaining screw 36, fasten screw 35.
Adjusting the horizontal mitre angle to
+- 45º
A
B
IMAGES
Checking
1.Raise locking bolt 14 (SC2500W, Turn the locking
knob 14 toward the left and press the button 53 to
move the head).
2.Move the head horizontally until it locks at +45º
(SC2500W, Rotate the knob 14 to adjust the
head in the desired position).
3.Check that the indicator for horizontal angles
marks exactly 45º. If not, proceed to adjusting.
4.Repeat the same sequence for the horizontal
angle at -45º.
Adjusting
1.Keep locking bolt 14 raised .
2.Loosen fastening screw of cam 33.
3.Move the whole of head and cutting table
horizontally until it locks at 45º.
4.Turn cam 33 against guide 13 until indicator 9
coincides with the 45º marking of indicator 7.
5.Tighten the fastening screw of cam 33.
6.Release locking bolt 14.
7.Repeat the same sequence for the horizontal
angle at 45º.
Adjustment for SC2500W
1.Turn the locking knob 14 to the left, and click the
button 53 to move the head.
2.Horizontally move the head assembly and cutting
table up to 45 degrees.
3.Release the button 53 of the locking knob 14 and
turn right to secure.
4.Repeat the same sequence for the horizontal
angle of -45 degrees.
Adjusting the vertical mitre angle to 90º
IMAGES
A
B
Checking
1.Release vertical adjustment of the head by
loosening control element or nut 15 (with Allen
key).
2.Move head to the right stopper (90º).
All manuals and user guides at all-guides.com
ENGLISH
R
I
G
30
3.Lock the vertical adjustment of the head by
tightening control element or nut 15 (with Allen
key).
4.Check the angle by means of a duly calibrated
angle chart or a goniometer (minimum precision
+- 5º) applying one of the surfaces thereof on
cutting table 6 and the other on cutting disk 21.
5.Should the side of the angle chart not adjust
exactly to the disk or if the direct measurement of
the goniometer reached a deviation of more than
+- 20º, proceed to adjusting.
Adjusting
1.Release the vertical adjustment of the head by
loosening control element or nut 15 (with Allen
key).
2.Move the head to the right stop (90º).
3.Remove retainer nut 18.
4.Place a goniometer (minimum precision +- 5º)
applying one of its sides on cutting table 6 and the
other on cutting disk 21.
5.Act on adjusting screw 19 until obtaining a
measurement of 90º.
6.Fasten the adjustment by tightening retainer nut
18 whilst retaining screw 19 with a screwdriver so
as to prevent it from moving.
7.Block the vertical adjustment of the head by
tightening control element or nut 15 (with Allen
key).
Adjusting the vertical mitre angle to 45º
IMAGES
A
E
Checking
2.Release the vertical adjustment of the head by
loosening control element
key)
3.Move head to the left stop (45º).
4.Block the vertical adjustment of the head by
tightening the control element
Allen key)
.
5.Check the vertical adjustment by means of a duly
calibrated angle chart or a goniometer (minimum
precision +- 5º) applying one of its sides on
cutting table 6 and the other on cutting disk 21.
6.Should the side of the angle chart not adjust
exactly to the disk or if the direct measurement of
the goniometer reached a deviation of more than
+- 20º, proceed to adjusting.
Adjusting
1.Release the vertical adjustment of the head by
loosening control element
key)
.
2.Move head to the left stopper (45º).
3.Remove retainer screw 17.
4.Check the vertical adjustment by means of a duly
calibrated angle chart or a goniometer (minimum
precision +- 5º) applying one of its sides on cutting
table 6 and the other on cutting disk 21.
30
or nut 15 (with Allen
or nut 15 (with
or nut 15 (with Allen

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis