7.9 Capacity ranges
Conditions: capacitors discharged and connected in accordance with the polar-
ity stated.
Overload protection: 1000 V
Measuring range
1 µF
10 µF
100 µF
1 mF
10 mF
Max. measuring time:
7.10 Frequency ranges
Overload protection: 1000 V
Measuring range
100 Hz
1 kHz
10 kHz
100 kHz
Minimum frequency: 1 Hz
Minimum sensitivity: > 5 V
7.11 Temperature ranges °C/ °F
Overload protection: 1000 V
Measuring range
- 40 °C to 400 °C
- 40 °F to 752 °F
*
The measuring accuracy of the K-type temperature sensor has to be added
to the specified measuring accuracy.
Wire temperature sensor (type K):
7.12 PEAK HOLD
DC/ AC V Measuring range
DC/ AC A Measuring range
8.
Measuring with the BENNING MM 7-1
8.1 Preparation for measuring
Store and use the BENNING MM 7-1 only under the correct temperature condi-
tions stated. Always avoid longer exposure to sunlight.
-
Check the rated voltage and rated current stated on the safety measuring
leads. The safety measuring leads supplied with the unit are suitable for the
rated voltage and current of the BENNING MM 7-1.
-
Check the insulation of the safety measuring leads. If the insulation is dam-
aged in any way, do not use the leads.
06/ 2011
AC/ DC
Resolution
1 nF
10 nF
100 nF
1 µF
10 µF
0.7 seconds for 1 nF - 1 mF
3 seconds for 1 mF - 10 mF
AC/ DC
Resolution
0.01 Hz
0.1 Hz
1 Hz
10 Hz
for V
SS
> 10 V
for V
SS
> 2 mA
for mA
SS
> 0.2 A
for A
SS
AC/ DC
60 mV
600 mV
6 V
60 V
600 V
1000 V
60 mA
600 mA
6 A
10 A
BENNING MM 7-1
± (1.2 % of reading + 2 digits)
± (1.2 % of reading + 2 digits)
± (1.2 % of reading + 2 digits)
± (1.2 % of reading + 2 digits)
± (1.2 % of reading + 2 digits)
± (0.1 % of reading + 2 digits)
± (0.1 % of reading + 2 digits)
± (0.1 % of reading + 2 digits)
± (0.1 % of reading + 2 digits)
1 Hz - 10 kHz
AC
10 kHz - 100 kHz
AC
AC
AC
Resolution
0.1 °C
0.1 °F
Measuring range: - 60 °C to 200 °C
Measurement accuracy: ± 2 °C
± (0.08 % of reading + 155 Digit)
± (0.08 % of reading + 152 Digit)
± (0.08 % of reading + 152 Digit)
± (0.08 % of reading + 152 Digit)
± (0.08 % of reading + 152 Digit)
± (0.08 % of reading + 152 Digit)
± (1.2 % of reading + 153 Digit)
± (1.2 % of reading + 153 Digit)
± (1.2 % of reading + 153 Digit)
± (1.2 % of reading + 153 Digit)
Measurement accuracy
Measurement accuracy
Measurement accuracy*
± (1 % of reading + 10 digits)
± (1 % of reading + 18 digits)
Measurement accuracy
Measurement accuracy
19