2.
Safety note
The instrument is built and tested in accordance with
DIN VDE 0411 part 1/ EN 61010-1
and has left the factory in perfectly safe technical condition.
To maintain this condition and to ensure safe operation of the appliance tester,
the user must observe the notes and warnings given in these instructions at
all times.
The unit may be used only in power circuits within the
overvoltage category III with a conductor for 600 V max. to
earth, or within overvoltage category II with a conductor for
1000 V against ground.
Only use suitable measuring leads for this. With measurements
within measurement category III, the projecting conductive part
of a contact tip of the measuring leads must not be longer than
4 mm.
Prior to carrying out measurements within measurement
category III, the push-on caps provided with the set and marked
with CAT III and CAT IV must be pushed onto the contact tips.
The purpose of this measure is user protection.
Remember that work on electrical components of all kinds is
dangerous. Even low voltages of 30 V AC and 60 V DC may be
dangerous to human life.
Before starting the multimeter up, always check it as well as all
measuring leads and wires for signs of damage.
Should it appear that safe operation of the appliance tester is no longer possible,
it should be shut down immediately and secured to prevent it being switched
on accidentally.
It may be assumed that safe operation is no longer possible:
-
if the instrument or the measuring leads show visible signs of damage, or
-
if the multimeter no longer functions, or
-
after long periods of storage under unfavourable conditions, or
-
after being subjected to rough transport.
In order to avoid danger,
-
do not touch the bare prod tips of the measuring leads
-
insert the measurement leads in the appropriately
designated measuring sockets on the multimeter
3.
Scope of delivery
The scope of delivery for the BENNING MM 11 comprises:
3.1 one BENNING MM 11
3.2 one software BENNING PC-Win MM 11
3.3 one serial data cable with USB 2.0 compatible connection
3.4 one safety measuring lead, red (L = 1.4 m)
3.5 one safety measuring lead, black (L=1.4 m)
3.6 one wire temperature sensor type K,
3.7 one adapter for wire temperature sensor,
3.8 one rubber protection frame,
3.9 one magnetic holder with adapter and strap
3.10 one compact protective pouch,
3.11 a 9 V block battery and two different fuses (fitted in unit as first equipment),
3.12 one operating instructions manual
Note on optional accessory:
-
Temperature probe (K-type) made of V4A tube (part no. 044121)
application: insertion probe for soft-plastic materials, liquids, gas and air
measuring range: - 196 °C up to 800 °C
dimensions: length = 210 mm, tube length = 120 mm, tube diameter =
3 mm, V4A
Parts subject to wear:
-
The BENNING MM 11 contains fuses as protection against overload:
One fuse, rated current 1 A quick-acting (600 V), 10 kA, D = 10 mm, L = 35
mm (part no. 749598) and one fuse, rated current 15 A quick-acting (600 V),
100 kA, D = 10 mm, L = 38 mm (part no. 749595).
-
The BENNING MM 11 is supplied by a fitted 9 V block battery (IEC 6 LR 61).
-
The above-mentioned safety measuring leads (tested accessories) cor-
respond to CAT III 1000 V and are approved for a current of 10 A.
03/ 2011
BENNING MM 11
17