Introduction
The JRGARANT safety valves JRG Code
1025/1028 protects storage-type (closed) water
heaters against excess loading due to pressure.
Function
When water is heated its volume increases,
which in a closed container creates a rise in
pressure. The built in non return valve prevents
water from flowing out of the water heater back
into the mains.
The safety valve opens when the pre-set
response pressure is reached and allows the
quantity of water causing the overpressure
to escape.
Adjusting pressure
JRGARANT JRG Code 1025
JRGARANT JRG Code 1028
(1-10 bar)  The desired response pressure must
be specified when ordering.
600 kPa (6 bar)
½"–1"
100-1000 kPa
½"–1"
It is not permitted to repair the safety
valve.
If you encounter problems, please
contact your sanitary contractor.
Applications and construction
(Paragraph 5.3 + 9 the SN EN 1491)
Water heater
Water
Maximum
content
heating
power
liter
kW
up to 200
75
200–1000
150
1000–5000
250
E
DN
Discharge
safety
valve
Drain line
½
½
¾
¾
1
1