Long heating-up time
Steam boiler is decalcified
Descale the steam boiler.
No steam
Indicator lamp - "water shortage" blinks
red and signal sounds
No water in the water reservoir.
Fill the water reservoir up to the "MAX"
marking.
Indicator lamp "water shortage" glows
red
No water in the steam boiler. Overheating
protection of the pump was triggered.
Turn off the appliance.
Fill the water reservoir
Turn on the appliance.
Water reservoir has not been inserted prop-
erly or is calcified.
Remove the water reservoir and rinse it.
Insert the water reservoir and press
downwards until it arrests.
Steam lever cannot be pressed anymore
Steam switch is secured with the lock /
child-proof lock.
Move the selector switch for the steam
volume to the front.
High water output
Steam boiler is decalcified
Descale the steam boiler.
Technical specifications
Power connection
Voltage
Protection class
Protective class
Performance data
Heating output
Operating pressure
max.
Heating time
Steam volume
Continuous steaming
Steam push max.
Filling quantity
Water reservoir
Boiler capacity
Dimensions
Weight (without acces-
sories)
Length
Width
Height
Subject to technical modifications!
– 12
EN
220-240 V
1~50/60 Hz
IPX4
I
1500 W
0,32 MPa
6 Minutes
40 g/min
100 g/min
0,8 l
0,5 l
4,1 kg
350 mm
280 mm
270 mm
21