5.5.3 Media
WARNING!
Risk of injury due to burst lines caused by a pressure surge.
If the valve with flow direction above the seat is used for liquid
media, a pressure surge can cause the lines and device to
burst.
▶ Do not use valves with flow direction above the seat for
liquid media.
Control medium: neutral gases, air
Flow media: Water, alcohols, oils, fuels, hydraulic fluids, saline
solutions, lyes, organic solvents, vapour, air, neutral gases.
6
All manuals and user guides at all-guides.com
6
Risk of injury from high pressure in the system.
▶ Before loosening lines or valves, switch off the pressure and
Risk of injury due to improper installation!
▶ Installation may be carried out by authorised technicians
Risk of injury due to unintentional activation of the system
and uncontrolled restart!
▶ Secure the system against unintentional activation.
▶ Following installation, ensure a controlled restart.
Risk of crushing due to moving pneumatic port!
▶ Do not touch the moving pneumatic port when opening and
▶ Do not reach into the area directly above and below the pilot
6.1
→ Ensure that (de-energized) pipelines are aligned before con-
→ Clear impurities from pipelines (seal material, metal chips,
Devices with welded connection:
Remove the actuator from the valve body:
English
Type 2060 INOX

Installation

INSTALLATION
DANGER!
bleed/drain the lines.
WARNING!
only and with the appropriate tools!
closing the device.
air port.

Preparatory work

necting the valve.
etc.).