Press "SETUP" icon to
setup page
Select setting unit
In/Outdoor & CH 1~7
temperature calibration
section
Pressure calibration
section
The rain, wind speed, UV
and light calibration use gain
method. The wind direction
is +/- 90 offset
The PM2.5 and PM10 is
+/-99 offset
(PM2.5 /10 calibration
setting is for optional
sensor only)
Current firmware version

6.4.1 CALIBRATION

1. User can input the offset and/or gain values for different parameters while current offset and
gain values are shown next to their corresponding blank.
2. Once completed, press
The current offset value will show the previous value that you entered, please input the new
value in the blank if any changes needed, the new value will effective once you press
icon in SETUP page.
SETTINGS
SETUP
Temperature
o
C
Indoor
Current offset: 0
Outdoor
Current offset: 0
CH 1
Current offset: 0
CH 2
Current offset: 0
CH 3
Current offset: 0
CH 4
Current offset: 0
CH 5
Current offset: 0
CH 6
Current offset: 0
CH 7
Current offset: 0
Range: -20.0 ~ 20.0
o
C
-36.0 ~ +36.0
o
F (Default: 0.0)
Pressure
Absolute Pressure Offset:
Relative Pressure Offset:
Setting Range:
-560~ 560hpa / -16.54 ~ 16.54inHg / -420 ~ 420mmHg
*Rain gain:
*Wind speed gain:
*Wind direction:
*UV gain:
*Light gain:
*PM2.5:
*PM10:
* Depends on the model
Firmware version: 1.00
ADVANCED page
at the bottom of the SETUP page
Apply
ADVANCED
Humidity %
Current offset: 0
Current offset: 0
Current offset: 0
Current offset: 0
Current offset: 0
Current offset: 0
Current offset: 0
Current offset: 0
Current offset: 0
Range: -20 ~ 20%
(Default: 0.0)
hpa
Current offset: 0
(Default: 0)
Current offset: 0
(Default: 0)
Current gain: 1.00
Range: 0.5 ~ 1.5(Default: 1.00)
Current gain: 1.00
Range: 0.5 ~ 1.5(Default: 1.00)
Current offset: +0
o
Range: -90 ~ 90(Default: 0
o
Current gain: 1.00
Range: 0.01 ~ 10(Default: 1.00)
Current gain: 1.00
Range: 0.01 ~ 10(Default: 1.00)
Current offset: 0
Range: -99 ~ 99(Default: 0)
Current offset: 0
Range: -99 ~ 99(Default: 0)
Browse
Upload
72
In/Outdoor & CH 1~7
humidity calibration
section
Select setting unit
Current offset value
is the value that you
set before to offset the
pressure reading
)
The firmware update
function only available
in PC/Mac web browser
Apply